If the Scanner/Mirrors Carriage Positioning Jigs are not available, follow these steps to
make the adjustment.
Rear
NOTE
If there is any gap between the Scanner and the
Scanner/Mirrors Carriage Positioning Jigs or
between the 2nd/3rd Mirrors Carriage and the jigs
when each is pressed up against the jigs, eliminate
the gap by turning the adjusting screws for the
front and rear Scanner Drive Cables.
4011D055AB
Front
1. Temporarily loosen the setscrews of the cable
holding plate of the Scanner Drive Cable.
4011D084AA
4011D055AB
2. Press the 2nd/3rd Mirrors Carriage up against
the front and rear rails and check that there is no
clearance at the front and rear ends.
3. If there is any clearance, turn the Scanner Drive
Cable adjusting screws at the front and/or rear as
necessary to eliminate the clearance.
Front
Rear
4. Move the 2nd/3rd Mirrors Carriage so that there
is a distance of 15.5 mm between the 2nd/3rd
Mirrors Carriage and the rail.
4011D107AB
4011D087AB
5. With the Scanner located at a position 21.6 mm
from the outer end face of the right side of the
Scanner, firmly tighten the setscrews of the cable
holding plate so that the Scanner runs parallel
with the end face both at the front and rear ends.
Front Rear