Mode Initial value
404
76543210
Bit: 00000001
HEX: 01
Bit Function
Logic
Description
01
7 Auto Panel Reset Bit7-0: Setting of whether or not auto
clear takes place after the speci-
fied time from the end of copying
or a key operation and also the
time setting.
1-minute steps
6 00000000 No Reset
5
00000001 1min.
4
-
3 11110000 240 min.
2 11111111 30 sec.
1 Other Setting
inhibit
0
Mode Initial value
405
76543210
Bit: 00001111
HEX: 0F
Bit Function
Logic
Description
01
7 Energy Save Mode Bit7-0: Setting of auto preheat time after
the specified time from the end of
copying or a key operation.
1-minute steps
6 00000000
Setting
inhibit
5 00000001 1 min.
4
-
3 00001111 15 min.
2
-
1 11110000 240 min.
0 Other
Setting
inhibit