FrameMaker Ver5.5E(PC) Di251/Di351 SWITCHES ON PWBs/TECH. REP. SETTINGS
05.03.01
S-43
Mode Initial value
406
25-cpm Copier
35-cpm Copier
76543210
Bit: 00111100
HEX: 3C
Bit Function
Logic
Description
01
7 Auto Power Off Bit7-0:
• Setting of whether or not to cut
OFF the power to the machine
after the specified time from
the end of copying or a key
operation, and also the time
setting
• When MODE 416 Bit0 "Auto
power off cancel" is set to
"Enabled", the setting
becomes "No".
1-minute steps
No FAX: Auto power OFF
With FAX: Heater OFF
Initial value for 25-cpm Copier
and 35-cpm Copier
6 00000000 OFF
5 00000001 1 min.
4
-
3 00001110 30 min. *1
2
-
1 00111100 60 min. *2
0
-
11110000 240 min.
Other
Setting
inhibit
Mode Initial value
407
76543210
Bit: 00000001
HEX: 01
Bit Function
Logic
Description
01
7 LCD Back-light Off Bit7-0: Setting of the back light OFF time
after the specified time from the
end of a key operation
1-minute steps.
6 00000000
Setting
inhibit
5
00000001 1min.
4
-
3 11110000 240 min.
2
Other
Setting
inhibit
1
0