162
8.3.7 Example of communications using the IP packet transfer
function
(1) When the request source device and request destination device have the same
network address
The following system configuration is used to explain an example of communications.
(a) Setting in the CPU module 1 and master station (station number 0)
1. Set the IP address in the CPU module 1.
Project window [Parameter] [PLC Parameter] "Built-in Ethernet Port Setting"
Ethernet device
(request source device)
192.168.1.1
: Route through which IP packets are passed (Routing parameters must be set.)
Network No.1
Network No.10
CPU module 1: 192.168.1.10
Master station
(station No.0)
: 192.168.2.125
CPU module 2: 192.168.10.10
Local station
(station No.2)
: 192.168.2.2
Network No.2
Ethernet device
(request destination device)
192.168.10.1