CHAPTER 11 PROGRAMMING
11
11.4 Using Link Special Relay (SB) and Link Special Register (SW)
(b) Checking the parameter status (own station)
1. When reception of parameters is completed, Parameter reception status (SB0077) turns off.
2. When a parameter has an error, Received parameter error (SB004D) turns on and the error code is
stored in Parameter setting status (SW004C).
3. When the parameter is set in the master/local module, contents of the parameter are stored in the
following link special relays (SBs) and link special registers (SWs).
Number Description Number Description
SB004D Received parameter error SW004C Parameter setting status
SB0077 Parameter reception status
Number Description Number Description
SB0040 Network type (own station)
SW0040 Network No.
SW0042 Station No.
SB0043 Mode (own station) SW0043 Mode status
SB0044 Station setting (own station) (1) SW0044 Submaster station No.
SB0045 Station setting (own station) (2) SW0046 Module type
SB0048 Control station status (own station) SW0058 Number of total slave stations (setting)
SB0060 Constant scan status SW0059 Number of total slave stations (current value)
SB0072 Scan mode setting information SW0063 Constant link scan set value
SB0073 Operation status specified for CPU stop error
SB0074 Reserved station specification status
SB0075 Error invalid station setting status
SB0076 Submaster station setting information
SB0078 Loopback function setting status
SB0079 Master station return specification information
SB007B Input data status of data link faulty station
SB007D Hold/clear status setting for CPU STOP
SB0080 IP address setting status
SB00C0 Reserved station setting status
SW00C0 to
SW00C7
Reserved station setting status
SB00D0 Error invalid station setting status
SW00D0 to
SW00D7
Error invalid station setting status