239
CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.1 List of Dedicated Instructions
(2) CC-Link dedicated instructions
These instructions are used for transient transmission with CC-Link IE Field Network-compliant devices.
(a) List of dedicated instructions
*1 The instruction cannot be executed to an intelligent device station from a local station. Execute it from a master station.
*2 Data cannot be written when the target station is the QSCPU.
(b) Transient transmission range of CC-Link dedicated instructions
It is possible to communicate with all stations in the same network.
Communication is not available with stations in other networks.
(3) Another dedicated instruction
The following instruction is used to set parameters for the master/local module of the own station.
(a) List of dedicated instructions
*1 Before executing the UINI instruction, check the versions of the CPU module, master/local module, and GX Works2.
( Page 546, Appendix 8)
(b) Transient transmission range of the dedicated instruction
Only the master/local module of the own station can be accessed.
Instruction Description Target network
Target station
(other station)
RIRD
*1
Reads the specified points of data from the target station device.
CC-Link IE Field
Network
CC-Link IE Field
Network compliant
devices (including
intelligent device
stations)
RIWT
*1*2
Writes the specified points of data to the target station device.
CC-Link IE Field
Network
CC-Link IE Field
Network compliant
devices
(including intelligent
device stations)
Instruction Description Target network
Target station
(other station)
CCPASET
Sets parameters for the master/local module.
CC-Link IE Field
Network
Access to other
stations is not
available.
(Own station only)
UINI
*1
Sets a station number for a local station.
CC-Link IE Field
Network
Access to other
stations is not
available.
(Own station only)
RIRD
Device
Send
buffer
CPU module
2594
2594
CPU moduleMaster/local module Master/local module
Device
Receive
buffer
Command
RIWT
Send
buffer
Device
CPU module
Command
2594
CPU moduleMaster/local module Master/local module
Receive
buffer
CCPASET
CPU module Master/local module
Command
Parameter setting
UINI
CPU module Local station
Command
Station number
setting