CHAPTER 7 PARAMETER SETTING
7
7.3 Network Configuration Settings
(2) How to configure the settings on the window in the table format
1. Set network setting parameters. ( Page 84, Section 7.2)
2. Open the setting window.
Project window [Parameter] [Network Parameter] [Ethernet/CC IE/MELSECNET]
button
3. Set parameters in the window.
4. Click the button.
Item Description Setting range
Assignment Method
Select a link device assignment method.
Points/Start: Enter the points and start numbers of link devices.
Start/End: Enter the start and end numbers of link devices.
Points/Start
Start/End
(Default: Start/End)
Module No.
The number of stations set in "Total Stations" of the network settings is
displayed.
Station No.
Select the station type (excluding the master station). Select the
station type same as that of the modules connected to the network.
1 to 120
(Default: Stations are numbered in
consecutive order by the number of
stations set in "Total Stations" in the
network setting.)
Station Type
Select the type of stations (excluding the master station). Select the
station type of modules actually connected to the network.
Remote I/O Station
Remote Device Station
Intelligent Device Station
Local Station
Sub-Master Station
(Default: Intelligent Device Station)