APPENDICES
A
Appendix 7 Mounting the Master/Local Module with a C Controller Module
Appendix 7.1 Setting the parameters using the buffer memory in the master/local module
For local stations
(g) Total number of slave stations (buffer memory address: 31744 (7C00
H
)) (needs to be
set for a master station)
When not using the submaster function
The number of connected slave stations is set (setting range: 1 to 120).
When using the submaster function
The number of connected slave stations is set. To use areas for a master station, set "the number of
connected slave stations + 1" (setting range: 1 to 121).
Bit Item Setting
b8 Data link faulty station setting
0: Clear
1: Hold
b9 Output setting during CPU STOP
0: Hold
1: Clear
b7
Fixed to 0
to b0b15 to b10 b9 b8
Fixed to 0