172
8.3.8 Communication speed
This section provides the results of communication speed measured using the IP packet transfer function. Use the
results as a reference.
(1) When a request source device and a request destination device are connected
to a CPU module
The results are based on measurement when FTP communications are performed with four modules connected
in star topology.
(a) System configuration
Device Description
Ethernet device (request source
device)
<FTP client>
CPU
Intel
®
Core 2 Duo processor 2.80GHz
OS
Microsoft
®
Windows
®
7 Professional Operating System
Ethernet board 1000BASE-T
FTP client application FFFTP
Ethernet device (request
destination device)
<FTP server>
CPU
Intel
®
Core i5 processor 2.67GHz
OS
Microsoft
®
Windows
®
7 Professional Operating System
Ethernet board 1000BASE-T
FTP server
application
FileZilla Server
Programmable controller
CPU module
Q06UDEHCPU
Sequence scan time: 1ms
Service processing setting: performed according to the
proportion of scan time (10%)
CC-Link IE Field
Network
Cyclic transmission
RX/RY setting : 128 points assigned to each station
RWw/RWr setting : 256 points assigned to each station
Transient transmission
N/A
Ethernet device (request destination device)
<FTP server>
Ethernet device (request source device)
<FTP client>
EthernetEthernet