546
Appendix 8 New and Improved Functions
The following table lists the new and improved functions.
: No restriction on serial number and version
New or improved function
Applicable module
(first five digits of
the serial number)
Applicable GX
Works2 version
Ring topology (loopback function) ( Page 178, Section 8.7)
Master station: "12072"
or later
Local station:
Version 1.40S or later
Parameter setting for a local station using the dedicated instruction (CCPASET)
( Page 359, Section 10.17)
"12072" or later
C Controller modules (parameter setting using buffer memory)
( Page 531, Appendix 7)
Auto-save of event history data ( Page 224, Section 9.5 (3))
Station numbers can be reset on a slave station where the station number has been
set on the CC-Link IE Field Network diagnostics.
"13032" or later Version 1.50C or later
The remote operation and clock settings can be batch-set to all stations on GX
Works2.
Version 1.56J or later
IP packet transfer function "14023" or later Version 1.77F or later
Submaster function "14023" or later Version 1.77F or later
Display of the disconnected station monitor area in the CC-Link IE Field diagnostics "14023" or later Version 1.77F or later
Station number setting in a program (the UINI instruction) "14042" or later Version 1.87R or later
C Controller modules (parameter setting using the setting/monitoring tools for the C
Controller module) ( Page 531, Appendix 7)
"14082" or later
Setting the network configuration setting in the CC IE Field configuration window Version 1.90U or later
The following operations can be performed from a master/local module to the slave
stations.
• Parameter setting
• Command execution
• Remote reset
"14102" or later Version 1.90U or later
Connection to MELSEC iQ-R series local stations and remote head modules
( Page 552, Appendix 10)
"16012" or later
Display of a receive frame error of the master station using the CC-Link IE Field
Network diagnostics
"16042" or later Version 1.513K or later
The following functions can be performed using the CC-Link IE Field Network
diagnostics.
• Display of a receive frame error of the slave station
• Switch of display name of the slave station
• When all the stations are disconnected, hold the network configuration before
disconnection in "Network Status" of the CC-Link IE Field Network diagnostic.
"16072" or later Version 1.519R or later
Network map update in the CC-Link IE Field Network diagnostics "17022" or later Version 1.530C or later
Data backup/restoration
Refer to the following.
iQ Sensor Solution Reference Manual
Change of the calculation method for maximum data link processing time when the
station is disconnected from or returned to the network, which is used for the link scan
time formula
"17022" or later
Display of the loopback station in the CC-Link IE Field Network diagnostics "17062" or later Version 1.535H or later
Normal display of the date and time of occurrence for error occurred during initial
processing of the CPU module in the event history
"17062" or later