343
CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.15 JP/GP.RIRD (Reading Data from the Target Station)
10.15JP/GP.RIRD (Reading Data from the Target Station)
This instruction reads data for the specified number of points from the device of the target station.
*1 Local devices and file registers set for each program cannot be used.
(1) Setting data
Setting
data
*1
Available devices
Internal device
(System, user)
File
register
R, ZR
Link direct device
J\
Intelligent function
module device
U\G
Index register
Zn
Constant
Others
Bit Word Bit Word K, H $
(S)
(D1)
(D2)
Setting data Description Set by Data type
Jn
Own station network No. (1 to 239, 254)
254: Network specified in Valid Module During Other Station Access
User
16-bit binary
Un
Start I/O number of the master/local module of the own station
(00 to FE
H
: Upper two digits of the I/O number expressed in three
digits)
(S) Start device of the own station where control data is stored
Device name
(D1) Start device of the own station where read data is stored
System
(D2)
The device of the own station that turns on for one scan upon
completion of the instruction.
If the instruction fails, (D2)+1 also turns on.
Bit
JP.RIRD
Start contact
GP.RIRD
Start contact
JP.RIRD Jn
GP.RIRD Un
(S) (D1) (D2)
(S) (D1) (D2)