313
CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.11 JP/GP.REQ (Remote RUN/STOP)
(d) REQ instruction execution timing
When the start contact starts up from OFF to ON, the processing is performed one time.
When completed
1 scan
REQ
Sequence scan
Start contact
Own station CPU
Target station CPU
Remote RUN/STOP
Master/local module
Network module
OFF
Completion device
(Device specified in (D2))
Completion status
indication device
(Device of (D2)+1)
Sequence scan
END0 END0
Channel 1
END0 END0 END0
END0 END0 END0 END0 END0