298
(c) RECV instruction execution timing
When data are stored in a channel of the own station, the corresponding RECV execution request flag
(SB0030 and SB0031) turns on.
Use the flag as a start contact and execute the RECV instruction.
Upon completion of the RECV instruction, the flag turns off.
When completed
For details on the RECV instruction execution time, refer to the following.
Page 289, Section 10.8 (2) (d)
When failed
(3) Checking error details
If the dedicated instruction fails, error details can be checked by either of the following methods:
(a) In GX Works2
Error details can be checked using the CC-Link IE Field Network diagnostics. ( Page 206, CHAPTER 9)
(b) Using devices
Completion status indication device ((D2)+1) turns on, and an error code is stored in Completion status
((S1)+1) of the control data.
According to the error code, check the error details and take a corrective action. ( Page 439, Section
12.5)
Number Name
SB0030 RECV execution request flag (1)
SB0031 RECV execution request flag (2)
1 scan
Error code
Arrival timeout
RECV
Sequence scan
RECV execution
request flag (2) (SB0031)
Own station CPU
Master/local module
Completion device
(Device specified in (D2))
Completion status
indication device
(Device of (D2)+1)
Completion status
(Device of (S1)+1)
END0 END0
Channel 2
END0 END0 END0