293
CHAPTER 10 DEDICATED INSTRUCTIONS
10
10.8 JP/GP.SEND (Sending Data to the Programmable Controller on Another Station)
(d) Program example
Write the following program to the CPU module of station No.0.
Stores send data in
D750 to D753.
Control data setting for
SEND instruction
Execution of
SEND instruction
Processing program upon completion
Processing program upon failure