516
SW0180
to
SW0187
Reserved station
cancel setting status
Stores if a reserved station setting is temporarily canceled.
0: No reserved station setting cancel
1: Reserved station function disable in progress
(Conditions)
This is enabled when Baton pass status (own station) (SB0047) is off.
Holds the data immediately before the error.
This is enabled only for normal stations in Baton pass status (each
station) (SW00A0 to SW00A7).
Stations higher than the maximum station No. are ignored.
SW0194 Loop test result
Stores a loop test result.
0: Completion
Other than 0: Abnormal end (Refer to the figure below.)
b0: More than one master station or submaster station exists.
b1: Station No. already in use
b2: Invalid station No.
b3: Reserved station specification error
(A station that exists on the network is set as a reserved station in
the master station.)
b4: All stations faulty
b5: Inconsistent total number of slave stations
b6: Station type setting error
b7: Loopback stations exist.
b8 to b15: Fixed to 0
(Master
station only)
×
Number Name Description
Availability
Master
station
(submaster
station)
Local
station
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
120 119 118 117 116 115 114 113
Each number in the table represents a station No.
is fixed to 0.
SW0181
SW0182
SW0183
SW0184
SW0185
SW0186
SW0187
SW0180
b15 b14 b1 b0
SW0194
to