539
APPENDICES
A
Appendix 7 Mounting the Master/Local Module with a C Controller Module
Appendix 7.1 Setting the parameters using the buffer memory in the master/local module
Parameters that cannot be set to local stations
Set the above-listed parameters that operate according to the settings of the master station in the master
station. To set other parameters, connect the Universal model QCPU with the master/local module and
configure the settings in the network parameter window of GX Works2.
(b) Precautions
When the network configuration setting data exceeds the total number of slave stations
If the number of set network configuration setting data exceeds the total number of slave stations, the data
will be ignored. Only the data set within the total number of slave stations are valid.
Applicable station numbers for reserved stations and error invalid stations
If the station number of a reserved station or error invalid station is outside the range set by total number of
slave stations and network configuration setting data, it is ignored. Only station numbers within the
specified ranges are valid.
Parameter error
If a parameter error occurs, check the error code stored in buffer memory and link special register (SW)
and take corrective actions.
Using a C Controller module on a local station
Disable "Block Data Assurance per Station" in the Network Parameter window for the master station.
Item Setting status
Network setting
Total Stations Depends on the setting in the master station.
Mode Online (Normal Mode)
Network Configuration
Settings
Station No.
Depends on the setting in the master station.
Station Type
RX/RY Setting
RWw/RWr Setting
Reserved/Error Invalid Station
Alias
Not set
Comment
Link Scan Mode Setting Asynchronous
Loopback Function Setting Depends on the setting in the master station.
Block Data Assurance per Station Not set
Network Operation
Settings
Parameter Name Not set
Refresh Parameters
Not set
Since link refresh cannot be performed, directly access the buffer
memory in the master/local module.
Interrupt Settings Not set (Interrupts cannot be performed.)
Interlink Transmission Parameters Not set (Interlink transmission cannot be performed.)
Routing Parameters
Not set
Transient transmission that requires routing parameters cannot be
performed.
For whether routing parameters are needed, refer to the following.
Page 119, Section 7.8
1. If a parameter is incorrect, an error code (D824
H
or D825
H
) is stored in Parameter
communication result (buffer memory address: 31742 (7BFE
H
)).
( Page 439, Section 12.5)
2. Check the error code stored in Parameter setting status (SW004C) and take corrective action.
( Page 439, Section 12.5)