8 Settings via the MICT
Rev. 03/2019 117
– Failure
– Analog Current Input
The red status display signals that the set failure threshold for the input has been
reached. If the lower limit of the signal is reached again, the status display is again
gray.
– Analog Voltage Input
The red status display signals that the set failure threshold for the input has been
reached. If the lower limit of the signal is reached again, the status display is again
gray.
– Ignition Output
The red status display signals a current misfire on at least one output. With a yellow
status display at least one misfire has occurred at one output since the last reset of the
counter.
– Misfire Rate
The misfire rate is displayed for the primary side and secondary side. The misfire rate on the
secondary side is only displayed if the secondary side diagnosis is activated (refer to
section Engine – Ignition Coils on page 94).
– Single Output
Displays the misfire rate of the output for which the most misfires were registered
during the last 32 cycles.
– All Outputs
Displays the misfire rate for all the ignition outputs for the past 32 cycles.
– The number of misfires per second are calculated by the MIC5 as follows:
2-stroke engine: Number of currently misfiring outputs x RPM / 60
4-stroke engine: Number of currently misfiring outputs x RPM / 60 / 2