EasyManua.ls Logo

NEC Storage Manager - iSM07102: State of PD(<aa>h) has become fault. (<bbb...b> productID=<ccc...c> SN=<ddd...d> No=<ee>h-<ff>h <ggg...g>)[_ALERT_]

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
97
iSM07102: State of PD(<aa>h) has become fault.
(<bbb...b> productID=<ccc...c>
SN=<ddd...d> No=<ee>h-<ff>h
<ggg...g>)[_ALERT_]
[Classification] ERROR
[Explanation] It indicates that trouble occurred in the physical disk (number: ee-ff) of disk
array (name: bbb...b).
For Windows, this message is target of ESMPRO Manager Report.
aa : Internal number indicating physical disk type
bbb...b : Disk array name
ccc...c : Product ID of disk array (S4300 Disk Array etc.)
ddd...d : Serial number of disk array
ee-ff : Physical disk number
ggg...g : Information of RANK or pool where the physical disk belongs
- PoolNo=<xxxx>h PoolName=<yyy...y>
Indicates pool information. (for the disk arrays with pool)
xxxx : Pool number
yyy...y : Pool name
- RankNo=<xx>h-<yy>h
Indicates RANK information. (for other than the disk arrays
with pool)
xx-yy : RANK number
[Measures] Check the status of resource with the trouble and perform the appropriate
maintenance.

Table of Contents

Other manuals for NEC Storage Manager

Related product manuals