EasyManua.ls Logo

NEC Storage Manager - iSM01411: Rejected: PerformanceMonitor is not available; iSM01412: Internal error. detail=<aaaa>; iSM01413: Usage: iSMsvr prf_update -t value; iSM01901: Function error has occurred. Function name=<aaa...a> Error code=<bbb> Error Message=<ccc...c>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
21
iSM01411: Rejected: PerformanceMonitor is not
available
[Explanation] It indicates that the performance monitor function is not available.
[Measures] Unnecessary
iSM01412: Internal error. detail=<aaaa>
[Explanation] It indicates that an internal error has occurred.
aaaa : Internal code
[Measures] Obtain information and restart the iSM.
iSM01413: Usage: iSMsvr prf_update -t value
[Explanation] It indicates that description of iSMsvr prf_update command is incorrect. A
specifiable format is shown in the message. Execute the command in valid
format.
This message is output on UNIX system.
[Measures] Check command format and retry.
iSM01901: Function error has occurred.
Function name=<aaa...a> Error
code=<bbb> Error Message=<ccc...c>
[Classification] ERROR
[Explanation] It is an internal error of iSMmainNT. This seems to be a problem depending on
Windows system.
This message is output on Windows system.
aaa...a : Function name
bbb : Error number
ccc...c : Error message
[Measures] Resolve the problem by checking the function name and the error number, and
restart the iSM server.

Table of Contents

Other manuals for NEC Storage Manager

Related product manuals