EasyManua.ls Logo

NEC Storage Manager - iSM13556: SCSI I;O error has occurred.; iSM13557: SCSI open has failed.; iSM13558: SCSI close has failed.

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
369
iSM13556: SCSI I/O error has occurred.
[Classification] ERROR
[Explanation] SCSI I/O error has occurred.
[Measures] A failure may be occurring in connection with disk array. Check status of FC
connection and then retry processing. If no problems are found in status of FC
connection, check the following for the specified volume. Then retry
processing.
- A special file or physical disk exists for the volume.
- The volume is not set to Not Ready or Not Available.
- Volume list was updated to the newest information after the configuration of
the disk array or system was changed.
- The target volume was registered in the volume list.
If RemoteDataReplication is used, a fault may have occurred in the link path to
the disk array on the remote side or the disk array may be in the shutdown or
freeze state. Check the state of the disk array on the remote side and the state of
the link path.
iSM13557: SCSI open has failed.
[Classification] ERROR
[Explanation] SCSI open error occurred.
[Measures] Check that the user with the access right to the volume exists or that the disk
number corresponding to the specified volume exists, and execute it again.
iSM13558: SCSI close has failed.
[Classification] ERROR
[Explanation] SCSI close error occurred.
[Measures] Check that the user with the access right to the volume exists or that the disk
number corresponding to the specified volume exists, and execute it again.