Chapter 2 Message List
39
iSM03120: Management of diskarray[<a>]
succeeded. name=(<bbb...b>)
detail=<cc-dddd>
[Classification] INFO
[Explanation] Succeeded in incorporating disk array specified by agent section (diskarray [a])
in environment definition file.
On Windows system, the message indicates that the disk array specified by
environment setting (setting of disk array information) diskarray [a] was
successfully incorporated.
a : Disk array specifying number in environment definition file
(UNIX system: 1 to 64, Windows system: 1 to 32)
bbb...b : Disk array name
cc-dddd : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Unnecessary
iSM03121: Management of diskarray[<a>] failed.
detail=<bb-cccc>
[Classification] WARNING
[Explanation] Failed in incorporating disk array specified by agent section (diskarray [a]) in
environment definition file.
On Windows system, the message indicates that the disk array specified by
environment setting (setting of disk array information) diskarray [a] was failed in
incorporating.
The reason for failure of management is indicated in the preceding message.
After that, the disk array may be automatically managed during operation of
iSM.
a : Disk array specifying number in environment definition file
(UNIX system: 1 to 64, Windows system: 1 to 32)
bb-cccc : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the message preceding this message, and take measures.