NEC Storage Manager - iSM07601: Attribute of LD has configured. (<aaa...a>); iSM07602: LD movement terminated. (<aaa...a>); iSM07611: Initialization of LD has failed. (<aaa...a> productID=<bbb...b> SN=<ccc...c> No=<dddd>h Name=<eee...e>)

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
175
iSM07601: Attribute of LD has configured.
(<aaa...a>)
[Classification] NOTICE
[Explanation] It indicates that attribute of LD is configured for the disk array (name: aaa...a).
aaa...a : Disk array name
[Measures] Unnecessary
iSM07602: LD movement terminated. (<aaa...a>)
[Classification] NOTICE
[Explanation] It indicates that configuration information is received again because the
inconsistency is detected in the disk array configuration information after LD
movement is completed for the disk array (name: aaa...a).
aaa...a : Disk array name
[Measures] Unnecessary
iSM07611: Initialization of LD has failed.
(<aaa...a> productID=<bbb...b>
SN=<ccc...c> No=<dddd>h
Name=<eee...e>)
[Classification] NOTICE
[Explanation] It indicates that data initialization is failed for the logical disk (number: dddd,
name: eee...e) in the disk array (name: aaa...a).
aaa...a : Disk array name
bbb...b : Product ID of disk array (S2100 Disk Array etc.)
ccc...c : Serial number of disk array
dddd : Logical disk number
eee...e : Logical disk name
[Measures] Check the status of the resource with the trouble and perform the appropriate
maintenance.