EasyManua.ls Logo

NEC Storage Manager - iSM14440: <aaa> Control Software update: status=failed; iSM14441: Storage Control Software update: status=<aaa...a>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
500
iSM14440: <aaa> Control Software update :
status=failed
[Classification] INFO
[Explanation] Indicates failure in updating storage control software.
aaa : Subjected resource
HD : Host director
DD : Disk director
SVP : Service processor
[Measures] The configuration or setting of the disk array may be changed. After updating it
to the newest information or restarting state monitoring, check current state and
execute again.
iSM14441: Storage Control Software update :
status=<aaa...a>
[Classification] INFO
[Explanation] It indicates that storage control software has been updated. Upon normal
operation, iSM14439 and iSM14442 messages are output also.
aaa...a : Command execution status
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.