Chapter 2 Message List
49
iSM03200: Control path access failed.
ip=<aaa...a> port=<bbbbb>
func=<ccc...c> errno=<ddd>
detail=<ee-ffff>
[Classification] ERROR
[Explanation] An error occurred in the socket communication with the disk array.
aaa...a : IP address
bbbbb : Port number
ccc...c : Function number
ddd : Error number
ee-ffff : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the network connection state to the disk array and the disk array state, and
remove the failure.
iSM03201: Control path access failed.
ip=<aaa...a> port=<bbbbb>
command=(<ccc...c>)
status=(<dd>/<ee>/<ff>/<gg>)
detail=<hh-iiii>
[Classification] ERROR
[Explanation] A command error occurred. A failure may exist in the disk array.
aaa...a : IP address
bbbbb : Port number
ccc...c : Command Descriptor Block of the issued command
dd : Status Byte
ee : Sense Key
ff : Additional Sense Code
gg : Additional Sense Code Qualifier
hh-iiii : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the disk array state, and remove the failure.