35
iSM03110: File (<aaa...a>) in diskarray[<b>] is
defined in the other specification.
detail=<cc-dddd>
[Classification] ERROR
[Explanation] It indicates that disk arrays specified by diskarray [b] overlap with each other.
The iSM server terminates abnormally.
This message is output on UNIX system.
aaa...a : Special file name
b : Disk array specification number (1 to 64) in the environment
definition file (agent section)
cc-dddd : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Correctly specify diskarray [b] in environment settings (specifying disk array
information) and restart the iSM server.
iSM03110: Disk (disk<aaa> (Port<bbb>
Bus<ccc> Target<ddd> Lun<eee>)) in
diskarray[<f>] is defined in the other
specification. detail=<gg-hhhh>
[Classification] ERROR
[Explanation] Disks specified in environment setting (setting of disk arrays) overlap with each
other. The iSM server terminates abnormally.
This message is output on Windows system.
diskaaa (Portbbb Busccc Targetddd Luneee): Disk information
f : Disk array specification number (1-32) of environment setting
(setting of disk array information)
gg-hhhh : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Correctly specify diskarray [f] in environment settings (specifying disk array
information) and restart the iSM server.