Chapter 2 Message List
614
iSMprfctl 030: Specified Logical Disk is invalid
[Explanation] The specification of the logical disk to be moved is invalid.
Check:
y if the specified logical disk exists in the specified disk array.
y if the specified logical disk is defined as a work disk for optimization.
y if the specified logical disk is defined as a cache resident disk.
[Measures] Review the specification of the logical disk to be moved, and then re-execute the
command.
iSMprfctl 031: Specified Optimization Work Disk
is invalid
[Explanation] The specification of the work disk for optimization is invalid.
Check:
y if the specified work disk for optimization exists in the specified disk array.
y if the attributes of the specified work disk for optimization are correct.
y if the specified work disk for optimization is defined as a cache resident disk.
[Measures] Review the specification of the work disk for optimization, and then re-execute
the command.
iSMprfctl 032: Disk Capacity is different
[Explanation] The logical disk to be moved and the work disk for optimization have a different
capacity, and the logical disk cannot be moved.
[Measures] Review the specification of the logical disk to be moved and the work disk for
optimization, and then re-execute the command.