EasyManua.ls Logo

NEC Storage Manager - iSM18503: Logical disk was unlinked from link-volume.(<aaa...a>,LV=<bbb...b>(<cccc>h), LD=<ddd...d>(<eeee>h)); iSM18601: Failed to change access mode. (<aaa...a>, LD=<bbb...b> (<cccc>h), mode=<ddd...d>), code=<eee...e>)

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
558
iSM18503: Logical disk was unlinked from
link-volume.(<aaa...a>,LV=<bbb...b>(<
cccc>h), LD=<ddd...d>(<eeee>h))
[Classification] INFO
[Explanation] It indicates that the volume was unlinked from the link-volume.
aaa...a : Disk array name
bbb...b : Logical disk name of link-volume
cccc : Logical disk number of link-volume
ddd...d : Logical disk name of destination-volume
eeee : Logical disk number of destination-volume
[Measures] Unnecessary
iSM18601: Failed to change access mode.
(<aaa...a>, LD=<bbb...b> (<cccc>h),
mode=<ddd...d>), code=<eee...e>)
[Classification] WARNING
[Explanation] It indicates that the volume access mode cannot be changed.
aaa...a : Disk array name
bbb...b : Logical disk name
cccc : Logical disk number
ddd...d : Access mode before change
eee...e : Error code indicating the type of abnormal state
[Measures] Check the status of disk array referring to other related messages and remove the
error cause, for example, by repairing the fault. Then, re-execute.

Table of Contents

Other manuals for NEC Storage Manager

Related product manuals