EasyManua.ls Logo

NEC Storage Manager - iSM20402: Unexpected error occurred. (phase=<aaa...a>); iSM20403: SCSI I;O error is detected. (device=aaaa, cdb =bbbb,status=cccc;dddd;ee;ff;gg)

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
597
iSM20402: Unexpected error occurred.
(phase=<aaa...a>)
[Classification] ERROR
[Explanation] An unexpected error has occurred.
aaa...a : Error detail code
[Measures] Check the details and re-execute.
iSM20403: SCSI I/O error is detected.
(device=aaaa, cdb
=bbbb,status=cccc/dddd/ee/ff/gg)
[Classification] ERROR
[Explanation] An error has occurred during SCSI command execution.
aaa...a : Failed device name
bbbb : Command Descriptor Block of issued command
cccc : SCSI command execution result
dddd : SCSI sense result
ee : SCSI sense information SenseKey
ff : SCSI sense information SenseCode
gg : SCSI sense information Qualifier
[Measures] Re-execute the command.

Table of Contents

Other manuals for NEC Storage Manager

Related product manuals