EasyManua.ls Logo

NEC Storage Manager - iSM10440: func error:report sc=<aaa>h, ec=<bbb...b>h; iSM10501: command option error:option=<aaaaaa>, status=<bbb...b>; iSM10502: command not execute:status=<aaa...a>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
244
iSM10440: func error:report sc=<aaa>h,
ec=<bbb...b>h
[Classification] NOTICE
[Explanation] It indicates that it failed in the transmission of trouble report to iSM client.
aaa : Code indicating location of error
bbb...b : Error code
[Measures] Check whether abnormalities have occurred in the configuring process on the
iSM server.
iSM10501: command option
error:option=<aaaaaa>,
status=<bbb...b>
[Classification] ERROR
[Explanation] It indicates that trouble occurred in the specified option.
aaaaaa : Option
<array | format | file | atg | csv>
bbb...b : Detail status
[Measures] Check the option specification and re-execute.
iSM10502: command not
execute:status=<aaa...a>
[Classification] ERROR
[Explanation] It indicates that the command execution environment was not prepared.
aaa...a : Execution environment status
[Measures] Check the command execution environment and re-execute.