Chapter 2 Message List
490
iSM14420: FW download(maintenance) :
resource=<aa>, PDG=<bb>h,
number=<cc>h, <cc>h...,
status=<ddd...d>
[Classification] INFO
[Explanation] It indicates that firmware downloading was executed.
aa : Subjected resource
PD : Physical disk
HD : Host director
DE : Disk enclosure
SVP : Service processor
bb : PD group number (Valid only when the subjected resource is a
PD.)
cc : Resource number or all
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), check whether the F/W file or
the state or subjected resource is normal.
iSM14421: Disk Array log init(maintenance) :
status=<aaa...a>
[Classification] INFO
[Explanation] It indicates that the initialization of internal log of Disk Array was executed.
aaa...a : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.