499
iSM14438: Set Port Platform : Platform=<aa>,
HD=<bb>h, Port=<cc>h,
status=<ddd...d>
[Classification] INFO
[Explanation] The OS type of the port has been set.
aa : Set platform
bb : Host director number
cc : Port number
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.
iSM14439: Shutdown Disk Array :
status=<aaa...a>
[Classification] INFO
[Explanation] Shutdown process of disk array started.
aaa...a : Command execution status
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or settings of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again. If accesses
from business server exist, terminate the accesses.