Chapter 2 Message List
494
iSM14428: Auto assignment mode:
mode=<aaa>, status=<bbb...b>
[Classification] INFO
[Explanation] It indicates that auto assignment mode was set.
aaa : on, off
bbb...b : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.
iSM14429: Expand LUN mode: HD=<aa>h,
Port=<bb>h, mode=<cc>,
status=<ddd...d>
[Classification] INFO
[Explanation] It indicates that Expand LUN mode was set.
aa : on, off
bb : Host Director number
cc : Port number
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.