Chapter 2 Message List
224
iSM10308: command: <aaa...a>, mv=<bbb...b>
(<cccc>h) <ddd...d>, rv=<bbb...b>
(<cccc>h) <ddd...d>, status=failed
(<ee>h/<ff>h/<gg>h)
[Classification] INFO
[Explanation] It indicates that it failed in accessing the pair expressed in MV or RV (failure of
SCSI protocol).
aaa...a : Command name
bbb...b : Logical disk name
cccc : Logical disk number
ddd...d : Disk array name
ee : Sense Key defined in SCSI specification
ff : Additional Sense Code defined in SCSI specification
gg : Additional Sense Code Qualifier defined in SCSI specification
[Measures] Check whether the configuration of disk array has been changed.
iSM10309: command: <aaa...a>, mv=<bbb...b>
(<cccc>h) <ddd...d>, rv=<bbb...b>
(<cccc>h) <ddd...d>, status=failed
(ec=<eee...e>)
[Classification] INFO
[Explanation] It indicates that it failed in accessing the pair expressed in MV or RV (failure
except for SCSI protocol).
aaa...a : Command name
bbb...b : Logical disk name
cccc : Logical disk number
ddd...d : Disk array name
eee...e : Error code
[Measures] Check whether the configuration of disk array has been changed.