NEC Storage Manager - iSM07155: State of PD(<aa>h) has become attn(powering up). (<bbb...b> productID=<ccc...c> SN=<ddd...d> No=<ee>h-<ff>h <ggg...g>)

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
120
iSM07155: State of PD(<aa>h) has become
attn(powering up).
(<bbb...b> productID=<ccc...c>
SN=<ddd...d> No=<ee>h-<ff>h
<ggg...g>)
[Classification] NOTICE
[Explanation] It indicates that the physical disk (number: ee-ff) of disk array (name: bbb...b) is
activated.
aa : Internal number indicating physical disk type
bbb...b : Disk array name
ccc...c : Product ID of disk array (S2800 Disk Array etc.)
ddd...d : Serial number of disk array
ee-ff : Physical disk number
ggg...g : Information of RANK or pool where the physical disk belongs
- PoolNo=<xxxx>h PoolName=<yyy...y>
Indicates pool information. (for the disk arrays with pool)
xxxx : Pool number
yyy...y : Pool name
- RankNo=<xx>h-<yy>h
Indicates RANK information. (for other than the disk arrays
with pool)
xx-yy : RANK number
[Measures] Unnecessary (It usually becomes ready within a few seconds. If the status does
not become ready, perform the appropriate maintenance because some trouble
may occur).