Chapter 2 Message List
449
iSM13751: Volume type is not ld.
(code=<aaa...a>-<bbb...b>-<bbb...b>-<
bbb...b>)
[Classification] ERROR
[Explanation] Specified volume type is not logical disk.
aaa...a : Process number
bbb...b : Detailed information (This code is not disorder reason but a
value for maintenance.)
[Measures] Check a specified volume type. Operations linked with replication
management allow specifying logical disk name only.
iSM13752: Timeout error has occurred in
iSM/Server.
(code=<aaa...a>-<bbb...b>-<bbb...b>-<
bbb...b>)
[Classification] ERROR
[Explanation] Time-out occurred in process of iSM server.
aaa...a : Process number
bbb...b : Detailed information (This code is not disorder reason but a
value for maintenance.)
[Measures] Loads on iSM server may be too heavy. Check status of iSM server and retry
command execution.