EasyManua.ls Logo

NEC Storage Manager - iSM03140: Management of control path in diskarray[<a>] failed. file=<bbb...b> func=<ccc...c> errno=<ddd> detail=<ee-ffff>; iSM03140: Management of control path in diskarray[<a>] failed. Disk=(disk<bbb> (Port<ccc> Bus<ddd> Target<eee> Lun<fff>)) func=<ggg...g> errno=<hhh> detail=<ii-jjjj>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
43
iSM03140: Management of control path in
diskarray[<a>] failed. file=<bbb...b>
func=<ccc...c> errno=<ddd>
detail=<ee-ffff>
[Classification] NOTICE
[Explanation] Failed in the inclusion of the control path.
This message is output on UNIX system.
a : Disk array specification number (1 to 64) in the environment
definition file (agent section)
bbb...b : Special file name
ccc...c : Function number
ddd : Error number
ee-ffff : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the FC connection state to the disk array and the disk array state, and
remove the failure.
iSM03140: Management of control path in
diskarray[<a>] failed.
Disk=(disk<bbb> (Port<ccc>
Bus<ddd> Target<eee> Lun<fff>))
func=<ggg...g> errno=<hhh>
detail=<ii-jjjj>
[Classification] NOTICE
[Explanation] Failed in the inclusion of the control path.
This message is output on Windows system.
a : Disk array specification number (1 to 32) in the environment
definition file (agent section)
diskbbb (Portccc Busddd Targeteee Lunfff): Disk information
ggg...g : Function number
hhh : Error number
ii-jjjj : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the FC connection state to the disk array and the disk array state, and
remove the failure.

Table of Contents

Other manuals for NEC Storage Manager

Related product manuals