Chapter 2 Message List
541
iSM16080: Definition change is successful.
function=<aaa...a> AUTH=<bbb...b>
[Classification] INFO
[Explanation] It indicates that the setting information change was successful.
aaa...a : Function name that has started
Alert : Error report
Heartbeat : Heartbeat report
Regulary : Periodical error report
RunningMainte : Scheduled maintenance report
bbb...b : Authentication method for accessing a mail server
NONE : Conventional authentication method
without SMTP authentication
SMTP_AUTH : SMTP Auth authentication method
POP_BEFORE_SMTP : POP before SMTP authentication
method
[Measures] Unnecessary (normal operation). Check the setting file if the operating function
is different from the setting.
iSM16081: Definition change error. ALIVEmail
function does not start.
[Classification] WARNING
[Explanation] It indicates that it failed to change the setting information. The driven function
does not operate till it succeeds.
[Measures] While trying to change the setting information with the iSM server running, the
definition error occurred. Correct the setting information error and execute the
change command again.