EasyManua.ls Logo

NEC Storage Manager - iSM11162: Disk Array Subsystem which can be operated by this program is not found.; iSM11163: Specified Disk Array Subsystem is not found.; iSM11164: Specified Disk Array Subsystem is not supported.

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
252
iSM11162: Disk Array Subsystem which can be
operated by this program is not
found.
[Classification] INFO
[Explanation] No such disk array as is an object of support of iSM can be found.
[Measures] Terminate the program. Check that the iSM server covers the disk array as
monitoring target, and also check the environmental definition of the iSM server
and the connection with the disk array. For more information, refer to Part III
“Operations” in the “User’s Manual”.
iSM11163: Specified Disk Array Subsystem is
not found.
[Classification] INFO
[Explanation] The specified disk array cannot be found.
[Measures] Terminate the program. Check that the iSM server covers the disk array as
monitoring target, and also check the environmental definition of the iSM server
and the connection with the disk array. For more information, refer to Part III
“Operations” in the “User’s Manual”.
iSM11164: Specified Disk Array Subsystem is
not supported.
[Classification] INFO
[Explanation] The specified disk array is not supported.
[Measures] Check whether Disk array name is correct and that the specified disk array is the
object disk array.