EasyManua.ls Logo

NEC Storage Manager - iSM14426: RANK rebuild time: RANK=<aa>h, PDG=<bb>h, Time=<cc>, status=<ddd...d>; iSM14427: LD format time: Time=<aa>, status=<bbb...b>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
493
iSM14426: RANK rebuild time : RANK=<aa>h,
PDG=<bb>h, Time=<cc>,
status=<ddd...d>
[Classification] INFO
[Explanation] It indicates that RANK rebuild time was changed.
aa : RANK number
bb : PD group number
cc : Rebuild time
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.
iSM14427: LD format time: Time=<aa>,
status=<bbb...b>
[Classification] INFO
[Explanation] It indicates that format time of Logical Disk was changed.
aa : Format time
bbb...b : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.