Chapter 2 Message List
167
iSM07461: State of POOL has become ready.
(<aaa...a> productID=<bbb...b>
SN=<ccc...c> No=<dddd>h
Name=<eee...e>)
[Classification] INFO
[Explanation] It indicates that the pool (number: dddd, name: eee...e) of a disk array (name:
aaa...a) has become ready.
aaa...a : Disk array name
bbb...b : Product ID of disk array (S2800 Disk Array etc.)
ccc...c : Serial number of disk array
dddd : Pool number
eee...e : Pool name
[Measures] Unnecessary
iSM07462: State of POOL has become fault.
(<aaa...a> productID=<bbb...b>
SN=<ccc...c> No=<dddd>h
Name=<eee...e>) [UC=<fff...f>
FC=<gg>][_ALERT_]
[Classification] ERROR
[Explanation] It indicates that trouble occurred in the pool (number: dddd, name: eee...e) of
disk array (name: aaa...a).
For Windows, this message is target of ESMPRO Manager Report, and also to
be target of ALIVE/Express Report via ESMPRO.
aaa...a : Disk array name
bbb...b : Product ID of disk array (S2800 Disk Array etc.)
ccc...c : Serial number of disk array
dddd : Pool number
eee...e : Pool name
fff...f/gg : Maintenance information
[Measures] Check the status of the pool with the trouble and perform the appropriate
maintenance.