EasyManua.ls Logo

NEC Storage Manager - iSM03225: Data can not be gotten sequentially during split mode.Disk=(disk<aaa> (Port<bbb> Bus<ccc> Target<ddd> Lun<eee>)) reason=(invalid sequence) detail=<ff-gggg>; iSM03300: SVP has restarted. ip=<aaa...a> detail=<bb-cccc>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
57
iSM03225: Data can not be gotten sequentially
during split mode.Disk=(disk<aaa>
(Port<bbb> Bus<ccc> Target<ddd>
Lun<eee>)) reason=(invalid
sequence) detail=<ff-gggg>
[Classification] ERROR
[Explanation] Obtaining data failed in command divided transfer. The message indicates
that retry processing could not obtain correct data either.
diskaaa (Portbbb Busccc Targetddd Luneee): Disk information
ff-gggg : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the status of the disk array, and remove the failure. Restart monitoring
manually if necessary.
iSM03300: SVP has restarted. ip=<aaa...a>
detail=<bb-cccc>
[Classification] INFO
[Explanation] Service processor (SVP) has become available for use.
aaa...a : IP address of service processor(SVP)
bb-cccc : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Unnecessary

Table of Contents