EasyManua.ls Logo

NEC Storage Manager - iSM14416: SPARE Rebuild(maintenance): RANK=<aa>h, PDN=<bb>h, PDG=<cc>h, Time=<dd>, status=<eee...e>; iSM14417: Set Rebuild time(maintenance): RANK=<aa>h, PDG=<bb>h, Time=<cc>h, status=<ddd...d>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
488
iSM14416: SPARE Rebuild(maintenance) :
RANK=<aa>h, PDN=<bb>h,
PDG=<cc>h, Time=<dd>,
status=<eee...e>
[Classification] INFO
[Explanation] It indicates that start of rebuilding using SPARE was instructed to specified
physical disk.
aa : RANK number
bb : Physical disk number
cc : PD group number
dd : Rebuild time
eee...e : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.
iSM14417: Set Rebuild time(maintenance) :
RANK=<aa>h, PDG=<bb>h,
Time=<cc>h, status=<ddd...d>
[Classification] INFO
[Explanation] It indicates that rebuild time was changed for the physical disk under rebuilding
process.
aa : RANK number
bb : PD group number
cc : Rebuild time
ddd...d : Execution state of the command.
good : Normal
failed(xxxx) : Error occurred (xxxx is error description)
[Measures] When an error occurs (status=failed was output), the configuration or setting of
the disk array may be changed. After updating it to the newest information or
restarting state monitoring, check current state and execute again.