Chapter 2 Message List
242
iSM10403: Disk array info (<aaa...a>
S/N=<bbb...b> Product-ID=<ccc...c>)
[UC=<ddd...d> FC=<ee>][_ALERT_]
[Classification] ERROR
[Explanation] It indicates additional information of disk array in which copy fault occurred.
For the pair composed by RemoteDataReplication, additional information of disk
array of each of MV and RV is output.
For Windows, this message is target of ESMPRO Manager Report, and also to
be target of ALIVE/Express Report via ESMPRO.
aaa...a : Disk array name
bbb...b : Serial number of disk array (16 characters)
ccc...c : Product ID of disk array (S2100 Disk Array etc)
ddd...d/ee : Maintenance information
[Measures] After remove cause of an error, restore the system with reference to description
about replication-specific HW fault in the “Data Replication User’s Manual
(Installation and Operation Guide for Windows)”.
iSM10410: comm error:report sc=<aaa>h,
ec=<bbb...b>h
[Classification] NOTICE
[Explanation] It indicates that telegram reception from iSM server failed.
aaa : Code indicating location of error
bbb...b : Error code
[Measures] Check whether abnormalities have occurred in the configuring process on the
iSM server.