NEC Storage Manager - iSM08181: Specified value is the same as current value(<a> times;minute); iSM08182: Can’t change display refresh rate(<aaa...a>:<bbb...b>)

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
197
iSM08181: Specified value is the same as
current value(<a> times/minute)
[Classification] NOTICE
[Explanation] The specified value is same as current display refresh rate. The command will be
ignored.
a : Specified refresh rate
[Measures] Unnecessary
iSM08182: Can’t change display refresh
rate(<aaa...a>:<bbb...b>)
[Classification] NOTICE
[Explanation] Display refresh rate cannot be changed for the causes shown in aaa...a.
aaa...a : cause
- stop all clients:
Refresh rate cannot be changed because a performance
monitoring screen is displayed.
- reduce threshold monitoring object:
Refresh rate cannot be changed due to excess number of
threshold monitoring object.
bbb...b : Disk array name
[Measures] Take the measures below.
- If the change was failed because a performance monitoring client was being
connected. (stop all clients)
Terminate all performance monitoring clients, then execute the command
again.
- If the change was failed due to excess number of threshold monitoring object.
(reduce threshold monitoring object) Reduce the threshold monitoring
objects from performance monitoring clients, execute the command again.