EasyManua.ls Logo

NEC Storage Manager - iSM09012: Request of change LD movement speed from <aaaa>(<bbb...b>) to <cccc>(<ddd...d>) in <eee...e> is rejected detcode=<ffffffff>; iSM09013: To get subsystem information failed from disk array=<aaa...a> detcode=<bbbbbbbb>

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
206
iSM09012: Request of change LD movement
speed from <aaaa>(<bbb...b>) to
<cccc>(<ddd...d>) in <eee...e> is
rejected detcode=<ffffffff>
[Classification] NOTICE
[Explanation] It indicates that the request to change the logical disk movement speed was
rejected.
aaaa : Logical disk number of moved material logical disk
bbb...b : Logical disk name of moved material logical disk
cccc : Logical disk number of work disk for Optimization
ddd...d : Logical disk name of work disk for Optimization
eee...e : Disk array name
ffffffff : Detail code
[Measures] Take the measures below.
y Check the specification of the logical disk for which the movement speed is
changed.
y Check for the disk array status according to the related messages, eliminate
the error cause (e.g., error recovery), and then re-execute the command.
iSM09013: To get subsystem information failed
from disk array=<aaa...a>
detcode=<bbbbbbbb>
[Classification] NOTICE
[Explanation] It indicates that the attempt to obtain such information related to the disk array as
configuration and attribution failed.
aaa...a : Disk array name
bbbbbbbb : Detail code
[Measures] Find the cause of the error on the disk array based on the information shown in
other messages, remove the cause and resume monitoring.