EasyManua.ls Logo

NEC Storage Manager - Chapter 4 Configuration Setting and Access Control Installation; 4.2 Configuration Setting and AccessControl Installation

NEC Storage Manager
710 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Message List
44
iSM03141: Management of control path in
diskarray[<a>] failed. file=<bbb...b>
command=(<ccc...c>) status=
(<dd>/<ee>/<ff>/<gg>) detail=<hh-iiii>
[Classification] NOTICE
[Explanation] Failed in the inclusion of the control path.
This message is output on UNIX system.
a : Disk array specification number (1 to 64) in the environment
definition file (agent section)
bbb...b : Special file name
ccc...c : Command Descriptor Block of the issued command
dd : Status Byte
ee : Sense Key
ff : Additional Sense Code
gg : Additional Sense Code Qualifier
hh-iiii : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the disk array state, and remove the failure.
iSM03141: Management of control path in
diskarray[<a>] failed.
Disk=(disk<bbb> (Port<ccc>
Bus<ddd> Target<eee> Lun<fff>))
command=(<ggg...g>)
status=(<hh>/<ii>/<jj>/<kk>)
detail=<ll-mmmm>
[Classification] NOTICE
[Explanation] Failed in the inclusion of the control path.
This message is output on Windows system.
a : Disk array specification number (1 to 32) in the environment
definition file (agent section)
diskbbb (Portccc Busddd Targeteee Lunfff): Disk information
ggg...g : Command Descriptor Block of the issued command
hh : Status Byte
ii : Sense Key
jj : Additional Sense Code
kk : Additional Sense Code Qualifier
ll-mmmm : Detail information (This code is not disorder reason but a value
for maintenance.)
[Measures] Check the disk array state, and remove the failure.

Table of Contents