Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 203
3.11.1.9 Configuring Auxiliary Alarm Card, Chassis, and Ethernet
Port External Alarm Parameters
Use the following CLI syntax to configure the external alarm parameters for the
Auxiliary Alarm card, 7705 SAR Ethernet ports (supported on all platforms with
Ethernet ports), and for the four alarm inputs on the fan module (for the 7705 SAR-8),
alarm connector (for the 7705 SAR-M (all variants), 7705 SAR-Wx (all variants),
7705 SAR-H, 7705 SAR-Hc, and 7705 SAR-X), and alarm module (for the
7705 SAR-18).
The output commands apply to the Auxiliary Alarm card only. The debounce and
normally commands do not apply to external alarm parameters configured on an
Ethernet port.
CLI Syntax: config# external-alarms
alarm alarm-id
chassis-alarming
description description-string
log
severity {critical | major | minor | warning}
thresholds
analog
level {lt | gt} millivolts
exit
trigger [any | all] {alarm-input1 |
alarm-input2... | alarm-input8}
exit
input alarm-input
debounce seconds
debounce detect detect-seconds clear
clear-seconds
description description-string
name name-string
normally {open | closed}
shutdown
exit
output alarm-output
description description-string
name name-string
shutdown
Example: config# external-alarms input alarm.d-1
config# external-alarms input alarm.d-2
config# external-alarms input alarm.d-3
config# external-alarms input alarm.d-4
config# external-alarms input alarm-1/1.d-1 name dinput1
config# external-alarms input alarm-1/1.d-2 name dinput2