7705 SAR Interfaces
222
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
revert-time 5
standby-signaling-master
exit
sap 1/2/1:501 create
description "Default sap description for service id 1"
ce-address 99.99.1.1
exit
spoke-sdp 1003:1 endpoint "Y" create
ce-address 99.99.1.2
precedence primary
no shutdown
exit
spoke-sdp 1004:1 endpoint "Y" create
ce-address 99.99.1.2
precedence 1
no shutdown
exit
no shutdown
exit
3.11.2.2 Configuring a Microwave Link
A microwave link can be configured on a 7705 SAR-8 or 7705 SAR-18 in order to
support a microwave connection from ports 1 through 4 on a Packet Microwave
Adapter card to an MPR-e radio that may be configured in standalone mode or Single
Network Element (Single NE) mode.
Use the following CLI syntax to configure a microwave link (in the example, the
MPR-e radios are configured in standalone mode):
CLI Syntax: config# port mw-link-id
[no] shutdown
mw
[no] hold-time {up hold-time-up | down
hold-time-down}
[no] peer-discovery
[no] protection
radio port-id main create
[no] database filename
name name-string
standalone
[no] tx-mute
radio port-id spare create
[no] database filename
name name-string
standalone
[no] tx-mute
[no] revert rps eps