EasyManua.ls Logo

Nokia 7705 SAR - 3.13.2.5 External Alarm Commands

Nokia 7705 SAR
902 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7705 SAR Interfaces
330
Interface Configuration Guide
3HE 11011 AAAC TQZZA Edition: 01
3.13.2.5 External Alarm Commands
external-alarms
Syntax external-alarms
Context config
Description This command enables access to the context to configure external alarm attributes on
7705 SAR Ethernet ports (supported on all platforms with Ethernet ports), on the Auxiliary
Alarm card, and on the four alarm inputs on the fan module (for the 7705 SAR-8), alarm
connector (for the 7705 SAR-M (all variants), 7705 SAR-H, 7705 SAR-Hc, and 7705 SAR-X),
and alarm module (for the 7705 SAR-18).
When configuring custom alarms for an Ethernet port, the port must be configured for
100Base-Tx operation with autonegotiation disabled.
alarm
Syntax [no] alarm alarm-id
Context config>external-alarms
Description This command creates or removes alarms.
The no form of this command disables the alarm attributes for the specified alarm. The alarm
must be in the shutdown state before the no form of the command can be performed.
Default n/a
Parameters alarm-id — specifies the alarm identifier
Values 1 to 2147483647
chassis-alarming
Syntax [no] chassis-alarming
Context config>external-alarms>alarm
Description This command generates output to chassis alarm relays and LEDs for the specified alarm.
The no form of this command disables the generation of output to chassis alarm relays and
LEDs.
Default chassis-alarming

Table of Contents

Related product manuals