Interface Configuration Guide 7705 SAR Interfaces
Edition: 01 3HE 11011 AAAC TQZZA 331
log
Syntax [no] log
Context config>external-alarms>alarm
Description This command generates raise/clear log events for the specified alarm and controls SNMP
trap generation for the raise/clear log events.
The no form of this command disables the generation of raise/clear log events.
Default log
severity
Syntax severity {critical | major | minor | warning}
Context config>external-alarms>alarm
Description This command configures the severity level for the specified alarm.
The alarm must be disabled before the severity level can be modified.
If the alarm generates raise/clear log events and SNMP traps (enabled by the log command),
the severity of the raise log events and SNMP traps is controlled by this configuration. The
severity level of the clear log events and SNMP traps is warning.
If the alarm generates output to chassis alarm relays and LEDs (enabled by the chassis-
alarming command), the severity level of the alarm output is controlled by this configuration.
For chassis relay alarms, only the critical, major and minor levels of severity apply. (There are
three LEDs that represent each of them.)
Default major
Parameters critical — specifies a critical alarm
major — specifies a major alarm
minor — specifies a minor alarm
warning — specifies a warning (not applicable for chassis relay alarms)